Electrical Parameters

Configure string sizing, inverter inputs, and understand how Branch tracks electrical data for your solar designs.

String Configuration

The string length is the number of panels connected in series to form one string. This is typically determined by your inverter's voltage window and the panel Voc.

ParameterWhere to SetDescription
String LengthBRANCHOPTIONSNumber of panels per string (e.g., 12, 14, 16)

Calculate string length properly

String length should be calculated based on your inverter's MPPT voltage window and the panel's Voc at the lowest expected temperature. This calculation is outside Branch's scope—use your preferred sizing tool or manufacturer guidelines.

Inverter Configuration

Configure how strings are distributed across your inverter's MPPT inputs.

ParameterExample ValuesDescription
Number of MPPTs2, 3, 4MPPT inputs on your inverter model
Strings per MPPT2, 3How many strings can connect to each MPPT
Total Strings per Inverter(calculated)MPPTs × Strings per MPPT

Example Configuration

For a SolarEdge SE7600H with 3 MPPT inputs and 2 strings per MPPT:

  • • Number of MPPTs: 3
  • • Strings per MPPT: 2
  • • Total strings per inverter: 6

Circuit Designation Format

When strings are assigned to inverters, Branch creates a circuit designation that identifies each string's location in the electrical system.

1/4a
1

Inverter Number

4

String Number

a

MPPT Input

This format makes it easy to:

  • Trace cables during installation — Know exactly where each string connects
  • Troubleshoot issues — Quickly identify which MPPT a problem string is on
  • Document the system — Clear labeling for construction documents and O&M

MPPT Letters

MPPTs are designated with lowercase letters starting from 'a':

a = MPPT 1b = MPPT 2c = MPPT 3d = MPPT 4

Cable Data Export

Branch tracks cable lengths for BOM generation and downstream engineering analysis.

CABLEEXPORT

Opens the cable export dialog showing all string and homerun cable data.

Data Available

FieldDescription
CircuitCircuit designation (e.g., "1/4a")
TypeString, Start Homerun, or End Homerun
LengthCable length in drawing units
InverterAssigned inverter number
Panel CountNumber of panels in the string

Export Features

  • Click to zoom — Double-click any row to zoom to that cable in the drawing
  • CSV export — Export data for spreadsheet analysis or BOM generation
  • Filter options — Filter by inverter, cable type, or other criteria

Best Practices

Match string length to inverter specs

Calculate string length based on your inverter's MPPT voltage window. Too few panels may not reach minimum voltage; too many may exceed maximum voltage.

Balance panels across groups

Use ADDPANELS to ensure each panel group has a panel count divisible by your string length. This avoids uneven strings and wasted panels.

Match panel counts per MPPT

Use INVBALANCE to open the Inverter Manager. It analyzes every inverter, suggests swaps to match panel counts on each MPPT, and can auto-balance your entire drawing with one click.

Verify cable data before export

Use CABLEEXPORT to review cable lengths and check for any outliers that might indicate routing errors before generating your BOM.